SA/R Series Rating Definitions
SA/R Series Rating Definitions
Propulsion
Heavy Duty(HD)
Typical Operation: | Allowable Load Factor is less than 100% of Rated Power. |
Allowable Cruising Speed is less than 100% of Rated Speed. | |
Operating hours is unlimited per year. | |
Typical Vessel Application: | Fishing Boats, Cargo Boats, Pusher Boats |
Medium Duty(MD)
Typical Operation: | Allowable Load Factor is up to 83% of Rated Power. |
Allowable Cruising Speed is up to 94% of Rated Speed. | |
100% of Rated Power is available intermittently for 8Hr per every 24Hr operation. | |
Operating hours is less than 6000Hr per year. | |
Typical Vessel Application: | Bay Area Tug Boats, Working Boats, Passenger Boats, Ferry Boats |
Light Duty(LD)
Typical Operation: | Allowable Load Factor is up to 75% of Rated Power. |
Allowable Cruising Speed is up to 91% of Rated Speed. | |
100% of Rated Power is available intermittently for 1Hr per every 6Hr operation. | |
Operating hours is less than 3000Hr per year. | |
Typical Vessel Application: | Pleasure Boats, Yachts, Patrol Boats, Fire Fighting Boats |
Auxiliary and Generator Set
Prime - Limited Running Time
Definition: | Prime-Limited Running Time is applicable for supplying continuous power paralleled with the utility for the limited short-time period. |
Typical Operation: | Allowable Average Load Factor for 24Hr is 100% of Rated Power. |
Over-Load of 110% can be used for less than 25Hr per year on emergency. | |
Yearly Average Load Factor is less than 100%. | |
Operating Hour is less than 500Hr per year. | |
Typical Application: | Seasonal Peak Cut, Stand-by Power Source |
Prime - Unlimited Running Time
Definition: | Prime-Unlimited Running Time is applicable for supplying power with varying load instead of the utility for an unlimited time. |
Typical Operation: | Allowable Average Load Factor for 24Hr is 80% of Rated Power. |
100% of Rated Power is available intermittently for 3Hr per every 24Hr operation. | |
Over-Load of 110% can be used for less than 25Hr per year on emergency. | |
Yearly Average Load Factor is less than 60%. | |
Operating Hour is unlimited. | |
Typical Application: | Stand alone Power Source, Daily Peak Cut, Power Source for Construction |
- In some cases with special condition or application, engines will not comply with the definition above.